Package
Canopy
20–1,250 kVA · IP23
Canopy sets
Quiet enough for sites with noise limits.
Give us the sound limit and its measurement point. A rating at 7 m and a limit at the site boundary refer to different positions.
Discuss a canopy setChoose a package around the plant room, the noise limit, how the set will arrive and whether it will move again.
Enclosures
Made in-house. Adapted to the site.
| Site decision | Open skid | Acoustic canopy | ISO container | Road-mobile trailer |
|---|---|---|---|---|
| Power span | 20–4,000 kVA | 20–1,250 kVA | 500–4,000 kVA | 20–650 kVA |
| When to choose | An existing plant room houses the equipment. | An outdoor pad has a defined noise boundary. | A large set needs a crane-in enclosure or a sea-freight route. | One set will serve successive sites. |
| Weather and noise | The room provides weather protection and acoustic treatment. | IP23; standard 75 dB(A) at 7 m. Custom attenuation: 68–75 dB(A) at 7 m. | 68–75 dB(A) at 7 m options. Cold-climate and desert kits cover −35 to +55 °C. | Sound-attenuated canopy; 68–75 dB(A) at 7 m options. |
| Fuel and switchgear | Coordinate the fuel supply and switchgear with the plant-room layout. | 8 h integral tank as standard; up to 24 h or an external tank by specification. Allow breaker access. | Specify the fuel connection and switchgear layout alongside the service aisle. | 8–24 h integral tank by rating. Plan the electrical connection at each stop. |
| Installation and transport | Check door clearance, foundations, ventilation and exhaust routing. | Provide a level pad, clear air paths and room to open service doors. | Check the 20 or 40 ft footprint, crane reach and delivery route. CSC plating is optional for sea freight. | Braked tandem-axle chassis. Confirm towing limits, site access and a level operating area. |
Enclosure architecture
Select a form to see its installation requirements and available options.
Package
Canopy
20–1,250 kVA · IP23
Canopy sets
Give us the sound limit and its measurement point. A rating at 7 m and a limit at the site boundary refer to different positions.
Discuss a canopy set
Package
Container
A set built into a 20 ft ISO container.
A set built into a 40 ft ISO container.
500–4,000 kVA · 20 or 40 ft
Container sets
Confirm the lift plan and service access before fixing the length. Specify optional CSC plating if the shipping route requires it.
Discuss a container set
Package
Open
20–4,000 kVA · Plant-room structural skid
Open sets
Use the room drawings to check airflow, exhaust routing and the path for maintenance. The homepage showroom depicts a 1,000–3,300 kVA utility-class skid within the full series.
Discuss an open set
Package
Trailer
20–650 kVA · Braked tandem axle
Trailer sets
Plan for the least accessible stop on the route. Give us the towing constraints and the longest interval between refuelling stops.
Discuss a trailer setThe site
We develop and make our own enclosures, so each package can be adapted to the place where it will stand.
Noise limits
How quiet must it be?
The enclosure is attenuated to the limit the site sets.
Climate
How hot, how cold?
The package is built for the temperatures it will meet, in heat and in cold.
Dust
What is in the air?
The package is built to keep dust away from the set.
Moisture
How wet does it get?
Rain and damp are kept out, so the set stays dry inside.
Salt
How near is the sea?
Materials and finishes are chosen to stand up to salt air.
A package made in-house can be adapted to its site, not just picked from a list.
The factoryWe require power for project, configured as sets.
Share preliminary load, duty and site parameters to begin technical scoping.